PDA Devices

 

*AMPLATZER® Duct Occluders for Patent Ductus Arteriosus Defect Closure*

AGA Medical designed AMPLATZER® Duct Occluders to allow closure of Patent Ductus Arteriosus (PDA) using a minimally-invasive catheter procedure instead of surgery.

Indications, contraindications, warnings, precautions and instructions for use can be found in the Instructions For Use supplied with each device.

 

AMPLATZER® Duct Occluder II

  AMPLATZER® Duct Occluder II

The AMPLATZER® Duct Occluder II (ADO II) for Patent Ductus Arteriosus utilizes Nitinol, a shape memory alloy of nickel and titanium. Each Occluder is made of a multi-layered, flexible, Nitinol wire mesh shaped into a cylindrical waist with retention discs on either end to secure it in the PDA. Fabric-free technology, which allows for low-profile devices and delivery systems, creates superior deliverability and expanded procedural options. The AMPLATZER Duct Occluder II can treat all classifications1, 2 of PDAs from 5.5 mm to less than 2.5 mm in diameter.

NOTE: This device is delivered using the AMPLATZER TorqVue LP Delivery System.

1 Krichenko et al: AM J Cardiolo 1989; 63:877
2 Not indicated for the treatment of “window” PDAs

 

 

AMPLATZER® Duct Occluder

 

AMPLATZER® Duct Occluder

The AMPLATZER® Duct Occluder for Patent Ductus Arteriosus also utilizes Nitinol, a shape memory alloy of nickel and titanium. Each Occluder is made of a Nitinol wire mesh shaped into a cylindrical plug with a flared collar to secure the Duct Occluder in the PDA. Polyester fabric inserts help close the hole and provide a foundation for growth of tissue over the occluder after placement.

 

The placement procedure typically takes place in a special room called a catheterization laboratory (“cath lab”) where minimally invasive, non-surgical procedures are performed. The AMPLATZER Duct Occluder is delivered to the correct place in the heart through a catheter, a small plastic tube, by an interventional cardiologist using x-ray and echocardiography. The physician deploys the occluder within the defect, where it expands, closing off the PDA.

 

 

Video Demonstrations

THE AMPLATZER Duct Occluder II

Duct Occluder II Placement

THE AMPLATZER Duct Occluder

Duct Occluder Placement

 

How Your Doctor Will Implant the Duct Occluder

What to expect before, during and after the procedure will vary. Discuss any questions or concerns you have with your doctor.


Read More

 

Patient Informational Guide on PDA Closure

 

PDA Patient Guide
The PDF provides a useful informational booklet about PDA and closure using the AMPLATZER® Duct Occluder. For additional information contact AGA Medical.

 